GEO®Hourly Building Design
GEO®Hourly is a patented geothermal HVAC design software executing hourly zone simulations to accurately analyze building energy, select heat pump equipment, and size ground loop heat exchangers for both residential and commercial buildings.
- This cloud-based software uses intelligent dual hourly design from built-in climate, building use, and equipment Libraries. Optimized Hybrid design supports cooling towers, fluid coolers, boiler, or auxillary electric heat.
- Traditional design methods often miss the mark on sizing heat pump equipment for specific building zones. The GEO®Hourly approach eliminates this issue by combining equipment selection and ground loop design into one seamless method with the shortest time workflow in the industry.
What GEO®Hourly does
Evaluates realistic heat pump operations, internal occupancy heat, and corrects heat pump equipment capacities and performance hour-by-hour for individual zones to mirror long-term earth energy transfer for all residential and commercial systems.
Size ground loops with precision by running simultaneous, 8,760-hour simulations for individual building zones. GEO®Hourly is a patented geothermal HVAC modeling software that captures unique schedules, dynamic heat pump performance, and hourly heating and cooling loads—overcoming the limitations of traditional tools that lump buildings under a single representative heat pump or rely on peak-only simulations with equivalent full-load hours (EFLH) or the simplified Bin Method.
The platform integrates National Research Laboratory Hourly weather data for over 470 U.S. and Canadian locations alongside ASHRAE design conditions. It includes 45 editable building-use profiles and a catalog of more than 650 ground-source heat pumps, removing the need to import third-party hourly load files.
Helps lower installation cost by optimizing ground heat exchanger length and matching heat pump equipment sizes accurately to specific building zones.
Calculates heating and cooling operating costs in each zone and evaluates annual economic payback using a unique, highly detailed yearly schedule.
Features built-in tools for evaluating hybrid configurations, including supplementary cooling towers, boilers, fluid coolers, or auxiliary electric heat.
Supports Vertical, Horizontal Trench and Horizontal Bore ground Loops.
Tracks the heat transferred between the building and the earth to analyze long-term ground thermal stability, while evaluating the long-term ground effect of the borehole to forecast the required design length to retain thermal stability.
Benefits Over Traditional Methods
The GEO®Hourly ground loop design method eliminates the reliance on equivalent full-load hours (EFLH) and peak-only heat pump simulations for each zone—the standard approach utilized by GLD-Design Day and Looplink-Pro software.
GEO®Hourly estimates the actual heat pump operational cycles as it models real-world thermodynamic flutuations.
While traditional guidelines suggest the equivalent full-load hours (EFLH) method provides a simple estimate of annual loads from peak loads during the feasibility phase, this approach is outdated for modern engineering. The final design requires a thorough, integrated analysis of site loads; GEO®Hourly replaces these simplified estimates by utilizing a patented, detailed continuous hour-by-hour zone analyses to optimize ground loop systems and calculate operating costs that eliminates the accuracy trade-offs of traditional EFLH approximations.
- “Equivalent full-load hours method provides a simple estimate of annual loads from peak loads needed to size ground heat exchangers at the feasibility study phase of a project; the final design should use a more thorough analysis of the site loads.” (2025 ASHRAE Handbook Chapter 35)
- “Equivalent full-load hours are used to account for the annual heat into and out of the ground as an alternate to a detailed hour-by-hour building energy simulation.” (ASHRAE Kavanaugh and Rafferty 2014)
| Feature / Metric | Equivalent Full-Load Hours (EFLH) (Static Estimation) |
GEO® Hourly Hour-by-Hour (Dynamic Simulation) |
|---|---|---|
| Project Phase | Feasibility / Preliminary screening only | Final engineering design / Construction documents |
| Data Input Model | Peak/block design load (Btu/hr) × static equivalent number of hours running at maximum peak capacity. | Independent 8,760-Hour Zone Modeling: Every zone separately simulates its own continuous interaction between occupancy schedules, building profiles, and heat pump performance. |
| Analysis Granularity | Simplified/aggregated estimation condensing annual usage into equivalent hours of peak-capacity operation. | Detailed 8760 hourly simulation performed Independently in every seperate zone based on climate and schedule libraries. |
| Peak vs. Off-Peak Fidelity | Estimated statically. Compresses building loads into simplified "peak versus "off-peak" at Annual Equivalent Operating Hours. | Simulated dynamically. Continuously tracks the migration of energy into and out of the ground independently for each zone. |
| Equipment Integration | Assumes full-capacity operation uniformly across annual calculated hours, ignoring part-load equipment capacities and efficiencies. | Simulates real-time heat pump operation correcting lab capacities hour-by-hour for single, dual, or variable equipment. |
| Heat Pump Part-Load Performance | This model ignores actual heat pump performance during off-peak hours and omits the efficiency degradation caused by part-load equipment cycling within individual zones. | Corrects rated capacity, power draw, and fluid flow rate dynamically based on entering fluid temperature for every hour adopting part-load degradation. |
| Accuracy Trade-offs | High margin of error; ignores variations in muti-stage heat pumps, often leads to over/under-sizing | Integrates accurate zone-level heat pump selection and multi-stage heat pumps operating at full or part load conditions. |
| Ground Loop Sizing | Relies on static peak loads and estimated hours, often resulting in loop over-engineering or high "safety margins". | Directly mirrors thermal transfer into and out of the earth to precisely optimize ground loop length. |
| Thermodynamic Behavior | Relies on peak-only single-point efficiencies of a heat pump model. | Simulates real-world operational cycles and ground thermal imbalance that are analyzed and forecast. |
| Hybrid & Auxiliary Support | Lacks dynamic sub-hourly checks, making hybrid system balancing and peak trimming less precise. | Simulates auxiliary electric heat strips and hybrid coolers/boilers dynamically to avoid sizing for rare peak anomalies. |
| Economic Insights | Provides generalized approximations of building energy expenditure and long-term costs. | Calculates precise zone operating costs, financial payback, and excess loop length financials dynamica. |
| Software Prevalence | Standard in legacy tools like GLD-Design Day and LooplinkPro | Patented simulation engine featuring simultaneous, multi-zone dynamic modeling for precise hour-by-hour energy and loop optimization. |
Traditional geothermal design has become a convoluted, error-prone process built on outdated shortcuts. Conventional Average Block Load methods rely on a single representative heat pump for capacity and efficiency across monthly or hourly simulations, even though real commercial buildings use dozens of water-source heat pumps varying in tonnage, manufacturer, compressor staging, and water-to-air versus water-to-water configurations. Because ground-side heat rejection and extraction depend directly on each unit’s instantaneous efficiency, aggregating space loads through one representative unit fails to capture true BTU transfer. A g-function only models how the earth responds to an incoming thermal load, meaning the traditional GLHEPro and GLD approach feeds distorted loads into the calculation. Another flawed method relies on a LoopLink PRO or GLD design-day approach driven by peak block-only zone load simulations and equivalent full-load hours (EFLH)—all of which result in over- or under-sized borefields.
Instead of untangling this modeling mess with complex external workarounds, designers routinely hedge against uncertainty by padding borefields with excessive safety margins. Across the industry, defensive over-sizing inflates upfront drilling costs, erodes project ROI, and stalls broader adoption. It is time to move past broken legacy workflows with a clean, integrated design start. GEO®Hourly eliminates both the modeling flaw and costly safety-factor padding by simulating each zone's specific heat pump performance, staging, and hybrid systems hour-by-hour directly against the loop in one streamlined step—delivering right-sized, bankable geothermal infrastructure that gets the industry moving forward.
The simplified bin method estimates geothermal energy use and system size by summing heat pump runtime across discrete outdoor temperature bins, though it sacrifices accuracy by relying on static internal heat gains and ignoring dynamic building factors. Because it omits thermal mass storage, solar gain, indoor humidity, simultaneous multi-zone loads, and dynamic occupancy or lighting schedules, designers must rely on a rule-of-thumb balance point temperature. A minor error of just a few degrees in this estimate can dramatically skew heating versus cooling runtime hours and distort seasonal ground heat exchange ratios.
Pairing this simplified shortcut with capacity-based sizing rules—such as the IGSHPA 2025 Design and Installation Guide, which sizes ground loops based on heat pump capacity rather than actual building loads—frequently results in an oversized ground heat exchanger. Furthermore, because the method ignores multi-year ground loop thermal drift, it cannot reliably predict long-term system performance. Ultimately, while the bin method is intended to trade accuracy for speed, it often takes longer to set up and execute than running a full dynamic simulation with GEO®Hourly.
Originally developed by ASHRAE in 1979 for air-source heat pumps, the bin method has never been recommended by the ASHRAE Handbook for residential or commercial geothermal systems. When forced into geothermal applications, it devolves into an unwieldy patchwork of static assumptions and temperature averages that often over- or under-engineers ground loops. In contrast, GEO®Hourly executes a true 8,760-hour, zone-by-zone simulation that dynamically models real-time building schedules, equipment performance, and long-term ground thermal stability. This approach eliminates the balance point errors, static internal gain assumptions, and decoupled loop temperatures inherent to bin-based sizing.
When a simulation engine or sizing tool uses rated heat pump capacity ("naked" and not connected to anything) instead of the zone's building design load, it corrupts both sides of a geothermal system: the indoor terminal equipment cannot properly condition the space, and the ground heat exchanger (borefield) is sized to the wrong heat rejection and extraction profile.
| Feature / Limitation |
Simplified Bin Method |
GEO® Hourly Hour-by-Hour |
|---|---|---|
| Calculation Approach | Groups annual weather into discrete temperature ranges ("bins") with no chronological sequence or "memory" bewteen hours. | Simulates all 8,760 Hours of the year sequentially using local climate data from 470+ North American locations. |
Balance Point & Deadband |
Requires multiple arbitary guesses to estimate a heat balance point, a cooling blance point, and the neutral deadband range between them––compounding errors that degrade accuracy and distort runtime hours. | Eliminates balance point deadband guessing by calculating actual hourly net loads directly from weather, envelope, and internal schedules. |
| Internal Heat Gains & Schedules | Assumes static internal heat (people, lights,equipment) across all hours in a temperature bin. | Appliess built-in hourly operating profiles accross 45 building types to reflect occupied vs. unoccupies hours. |
| Equipment Modeling | Often lumps building loads together or uses "naked" Lab uncorrected equipment capacity and efficiency data (not connected to anything). | Simulates zone-specific heat pumps (single, dual, or variable speed) at each operating stage hour-by-hour using corrected heat pump data. |
| Ground Loop Sizing Basis | Often paired with capacity-based formulas (like the IGSHPA 2025 guide), describes sizing loops to full heat pump capacity rather than building load and oversizing the Loop. | Sizes the borefield using actual hourly building loads and dynamically adjusted heat pump performance prevents both interior comfort failure and long-term ground loop thermal drift. |
| Heat Pump Part-Load Performance | Ignores actual heat pump performance during off-peak hours and calculates loads in isolation for each bin, often omitting the efficiency degradation caused by part-load cycling. | Corrects rated capacity, power draw, and fluid flow rate dynamically based on entering fluid temperature for every hour adopting part-load degradation. |
The simplified bin method relies on compounding guesses—static internal gains, estimated deadband ranges, and capacity-based sizing rules—that drive up installation costs. GEO® Hourly eliminates the guesswork with automated 8,760-hour zone simulations that match actual building loads to real equipment curves, cutting unnecessary borehole footage and capital expenses.
Why GEO®Hourly
GEO®Hourly uniquely integrates heat pump equipment selection software, energy model software, and ground heat exchanger design software as an online application.
- Designing HVAC systems by Zone is the preferred method applied by engineers. GEO®Hourly databases offer the selection of many types and brands of heat pump equipment in each zone for matching building zone Btu design loads.
- The key to designing a good geothermal system is selecting the proper sized heat pump equipment in each zone and matching the design temperature for cooling and heating that precludes the heat pump from running out of capacity over the range of water temperatures coming from the ground. This is accompanied by an integrated design method that adapts each zone to the heat pump equipment stage applying hourly parameters; calculating heat transfer in and out of the ground and operating cost.
- Industry heat transfer physics: ASHRAE 2025 HVAC Application Handbook Chapter 35 describes the heat transfer physics used by GEO® Hourly. ASHRAE USA and Canada design weather data is used with permission.
Captures the dynamic weather, occupancy schedules, and internal loads that standard peak design-day, simplified Bin Method, and average monthly load methods omit for a definitive design.
Avoids oversizing ground loops, which reduces initial drilling and installation expenses while maintaining system performance.
Eliminates the need for complex third-party software integration to convert monthly loads into hourly operational profiles.