GEO® Hourly Building Design
GEO® Hourly – patented zone-by-zone building/HVAC geothermal design software performs hour-by-hour simulations and evaluates energy, heat pump equipment selection, and ground Loop/ground heat-exchanger sizing.
- This cloud-based software uses intelligent simultaneous dual hour-by-hour design from built-in climate, building use, and equipment Libraries. Optimized Hybrid design supports cooling towers, fluid coolers, boiler, or auxillary electric heat.
- Traditional design methods fail to help designers select the proper heat pump equipment size required for each building zone. The Geo® Hourly approach to geothermal design solves this issue by integrating heat pump equipment selection and ground loop design into a single method.
What GEO® Hourly does
Evaluates realistic heat pump operations, internal occupancy heat, and corrects heat pump capacities and performance hour-by-hour for individual zones.
- GEO® Hourly corrects lab-tested heat pump operations, internal occupancy heat, and corrects heat pump equipment capacities and performance hour-by-hour for individual zones.
- By integrating realistic equipment sizing directly with ground heat exchanger (loop) design, the software generates a highly precise mirror of long-term thermal energy transfer into and out of the earth.
Simulates building performance, zone loads, and heat pump operation for unique hourly schedules rather than relying on sizing loops with simplified monthly averages or single design days.
Includes National Research Laboratory Hourly weather data for over 470 locations across the United States and Canada. Has 45 Building Uses. Includes over 1,000 Ground Source heat pumps.
Helps lower installation cost by optimizing ground heat exchanger length and matching heat pump equipment sizes accurately to specific building zones.
Performs detailed houly analysis (unique yearly schedule) to calculate heating and cooling operating costs in each zone and the annual economic payback.
Built in tools for evaluating hybrid configurations, such as incorporting supplementary cooling towers,boilers fluid coolers or auxillary electric heat.
Designs Vertical, Horizontal Trench and Horizontal Bore ground Loops.
Integrates the heat transferred between the building and the ground and analyses the long-term ground thermal stability.
Benefits Over Traditional Methods
GEO® Hourly estimates the actual heat pump operational cycles as it models real-world thermodynamic flutuations.
While traditional guidelines suggest the equivalent full-load hours (EFLH) method provides a simple estimate of annual loads from peak loads during the feasibility phase, this approach is outdated for modern engineering. The final design requires a thorough, integrated analysis of site loads; GEO® Hourly replaces these simplified estimates by utilizing a patented, detailed hour-by-hour method that eliminates the accuracy trade-offs of traditional EFLH approximations.
Comparison of Method
| Feature / Metric | Equivalent Full-Load Hours (EFLH) | GEO® Hourly Hour-by-Hour Simulation |
|---|---|---|
| Project Phase | Feasibility / Preliminary screening only | Final engineering design / Construction documents |
| Data Input Model | Peak/block design load (Btu/hr) × static equivalent number of hours running at maximum peak capacity. | Independent 8,760-Hour Zone Modeling: Every zone separately simulates its own continuous interaction between occupancy schedules, building profiles, and heat pump performance. |
| Peak vs. Off-Peak Fidelity | Estimated statically. Compresses building loads into simplified "peak hours versus "off-peak hours" blocks based on occupied use estimates. | Simulated dynamically. Tracks the continuous hour-by-hour migration of energy in and out of the ground zone-by-zone. |
| Heat Pump Part-Load Performance | Relies on catalog single-point nominal efficiencies or rating conditions before corrections. | Corrects rated capacity, power draw, and fluid flow rate dynamically based on entering fluid temperature for every hour. |
| Thermodynamic Behavior | Assumes a nominal size single heat pump model | Simulates real-world operational cycles and ground thermal imbalance or decay |
| Accuracy Trade-offs | High margin of error; ignores variations in muti-stage heat pumps, often leads to over/under-sizing | Integrates accurate zone-level heat pump selection and heat pumps operating at full and part load conditions. |
| Software Prevalence | Standard in legacy tools like GLD-Design Day and LooplinkPro | Proprietary multi-patented engine for advanced dynamic simulation |
Captures the dynamic weather, occupancy schedules, and internal loads that standard peak design-day and average monthly load methods omit for a definitive design.
Avoids oversizing ground loops, which reduces initial drilling and installation expenses while maintaining system performance.
Eliminates the need for complex third-party software integration to convert monthly loads into hourly operational profiles.
Why GEO® Hourly
GEO® Hourly uniquely integrates heat pump equipment selection software, energy model software, and ground heat exchanger design software as an online application.